Electrostatic Problem of Cyclotron chamber at Peak High Voltage. Mainly used for studying the ion source region DEE Voltage: 10kV [April 25, 2005 - Tim Koeth] ® kprob=0, ! Poisson or Pandira problem xjfact=0.0, ! Electrostatic problem dx=0.01, ! Mesh interval icylin=0, ! Cartesian coordinates nbsup=0, ! Dirichlet boundary condition at upper edge nbslo=0, ! Dirichlet boundary condition at lower edge nbsrt=0, ! Dirichlet boundary condition at right edge nbslf=0, ! Dirichlet boundary condition at left edge ltop=10 & ! Maximum row number for field interpolation &po x=-13.970, y= 1.905 & !this outlines the grounded chamber with new dummy DEE &po x= 0.318, y= 1.905 & &po x= 0.318, y= 1.111 & &po x= 1.270, y= 1.111 & &po x= 1.270, y= 1.905 & &po x= 13.970, y= 1.905 & &po x= 13.970, y=-1.905 & &po x= 1.270, y=-1.905 & &po x= 1.270, y=-1.111 & &po x= 1.270, y=-1.000 & &po x= 0.120, y=-1.000 & &po x= 0.120, y=-1.111 & &po x= 0.318, y=-1.111 & &po x= 0.318, y=-1.905 & &po x=-13.970, y=-1.905 & &po x=-13.970, y= 1.905 & ® mat=0,voltage=0.0,ibound=-1 & ! &po x= -0.200, y=-1.000 & &po x= -0.100, y=-1.000 & &po x= -0.100, y=-1.111 & &po x= -0.250, y=-1.111 & &po x= -0.250, y=-1.500 & &po x= -0.200, y=-1.500 & &po x= -0.200, y=-1.000 & !varying gap to see how the ion source gets killed ® mat=0,voltage=10000.0,ibound=-1 & ! this outlines the DEE (at widest - symmetry - point) 10kV &po x=-13.018,y= 1.270 & &po x= -0.318,y= 1.270 & &po x= -0.318,y= 1.111 & &po x=-12.859,y= 1.111 & &po x=-12.859,y=-1.111 & &po x= -0.318,y=-1.111 & &po x= -0.318,y=-1.270 & &po x=-13.018,y=-1.270 & &po x=-13.018,y= 1.270 & !attempt to place filament ® mat=0,ibound=-1,voltage=-130.0 & &po x=0.125,y=-1.500 & &po nt=2,r=0.125,theta=90., x0=0.000,y0=-1.500 & &po nt=2,r=0.125,theta=180.,x0=0.000,y0=-1.500 & &po nt=2,r=0.125,theta=270.,x0=0.000,y0=-1.500 & &po nt=2,r=0.125,theta=360.,x0=0.000,y0=-1.500 &